Entity measured_flow_stream


Attribute                                 Flags   Data Type

From fluid_flow_stream:
   data_collection                        IV      set[0 .. N] of (data_collection)

                                          Indicates the data collections that include this
                                          instance of E and P data. 

   graphical_element                      IV      set[0 .. N] of (graphical_element)

                                          Specifies one or more graphical elements which
                                          are depicting this data item. 

   datum_for_ranking                      IV      set[0 .. N] of (object_ranking)

                                          Indicates that an object is being used as a basis
                                          for comparison with another object. 

   object_of_ranking                      IV      set[0 .. N] of (object_ranking)

                                          Indicates that an object is being classified in
                                          a rank order based on its characteristics. 

   subject_of_contract                    I       set[0 .. N] of (contract)

                                          These are the contracts that specify information
                                          about the business object, and the business object
                                          is subject to the terms of these contracts. 

   derived_interest                       IV      set[0 .. N] of (derived_interest_makeup)

                                          These are the ownership fractions for business
                                          associates of this business object. 

   subject_of_contract_designation        IV      set[0 .. N] of (contract_designation)

                                          This defines the contract designations that are
                                          made for this business object. For example, this
                                          may be the contract designations that define the
                                          specific interest ownership fractions of the business
                                          object as it is bought and sold. 

   guideline_or_privilege                 IV      set[0 .. N] of (guideline_or_privilege)

                                          These are the guidelines, limitations, regulations
                                          or privileges that are specifically defined for
                                          this business object. Other general guidelines,
                                          etc., that apply to this business object are defined
                                          via the typical and class relationships (if any)
                                          defined for this business object. 

   guideline_or_privilege_compliance      IV      set[0 .. N] of (guideline_or_privilege_compliance)

                                          These are the designations of compliance with
                                          guidelines, limitations, regulations and privileges
                                          that are made for this business object. Each compliance
                                          statement describes the state of compliance for
                                          a specified guideline, limitation, regulation
                                          or privilege for a period of time. 

   satisfy_obligation                     IV      set[0 .. N] of (contractual_obligation)

                                          These are the contractual obligations that this
                                          business object is designated as fulfilling, either
                                          completely or partially. 

   description                            I       ndt_comment

                                          A remark about the performance history. 

   product_flow_network_unit_port         MI      product_flow_network_unit_port

                                          This is the port at which this fluid flow stream
                                          is defined. 

   pty_curve_fit_result                   IV      set[0 .. N] of (pty_curve_fit_result)

                                          This is the description of flow stream behavior
                                          as properties defined along a time axis after
                                          mathematically fitting them to a mathematical
                                          model. 


fluid_phase                               U       fluid_phase

                                          This is the fluid phase that is being described
                                          by this fluid flow stream. The physical properties
                                          of the fluid in the stream are defined for the
                                          fluid phase. 

pty_fluid_phase_ratio                     V       set[0 .. N] of (pty_fluid_phase_ratio)

                                          may have a property of 

pty_flow_rate_mole_basis                  V       set[0 .. N] of (pty_flow_rate_mole_basis)

                                          may have a property of 

pty_transient_volume                      V       set[0 .. N] of (pty_transient_volume)

                                          may have a property of 

pty_flow_rate_mass_basis                  V       set[0 .. N] of (pty_flow_rate_mass_basis)

                                          may have a property of 

pty_flow_rate_volume_basis                V       set[0 .. N] of (pty_flow_rate_volume_basis)

                                          may have a property of 

pty_basic_sediment_and_water              V       set[0 .. N] of (pty_basic_sediment_and_water)

                                          may have a property of 

pty_transient_density_liquid              V       set[0 .. N] of (pty_transient_density_liquid)

                                          may have a property of 

pty_transient_density_vapor               V       set[0 .. N] of (pty_transient_density_vapor)

                                          may have a property of 

pty_inflow_performance_ratio              V       set[0 .. N] of (pty_inflow_performance_ratio)

                                          may have a property of 

End of entity measured_flow_stream


M - mandatory, U - unique, I - inherited, V - inverse, N - named type


EPICENTRE schema version 2.1

INDEX august POSC Mobil ABOUT